Characteristics of a New X-Ray Imaging System for Interventional Procedures: Improved Image Quality and Reduced Radiation Dose
Creators
- 1. Medical University of Vienna, Section of Cardiovascular and Interventional Radiology, Department of Biomedical Imaging and Image-guided Therapy (Austria)
- 2. Yale University School of Medicine, Department of Radiology and Biomedical Imaging (United States)
- 3. Image-Guided Therapy Systems, Philips Healthcare (Netherlands)
- 4. The Johns Hopkins Hospital, Russell H. Morgan Department of Radiology and Radiological Science, Division of Vascular and Interventional Radiology (United States)
- 5. PreScience Labs (United States)
Description
Purpose
To compare image quality and radiation exposure between a new angiographic imaging system and the preceding generation system during uterine artery embolization (UAE).Materials and Methods
In this retrospective, IRB-approved two-arm study, 54 patients with symptomatic uterine fibroids were treated with UAE on two different angiographic imaging systems. The new system includes optimized acquisition parameters and real-time image processing algorithms. Air kerma (AK), dose area product (DAP) and acquisition time for digital fluoroscopy (DF) and digital subtraction angiography (DSA) were recorded. Body mass index was noted as well. DF image quality was assessed objectively by image noise measurements. DSA image quality was rated by two blinded, independent readers on a four-rank scale. Statistical differences were assessed with unpaired t tests and Wilcoxon rank-sum tests.Results
There was no significant difference between the patients treated on the new (n = 36) and the old system (n = 18) regarding age (p = 0.10), BMI (p = 0.18), DF time (p = 0.35) and DSA time (p = 0.17). The new system significantly reduced the cumulative AK and DAP by 64 and 72%, respectively (median 0.58 Gy and 145.9 Gy*cm2 vs. 1.62 Gy and 526.8 Gy*cm2, p < 0.01 for both). Specifically, DAP for DF and DSA decreased by 59% (75.3 vs. 181.9 Gy*cm2, p < 0.01) and 78% (67.6 vs. 312.2 Gy*cm2, p < 0.01), respectively. The new system achieved a significant decrease in DF image noise (p < 0.01) and a significantly better DSA image quality (p < 0.01).Conclusions
The new angiographic imaging system significantly improved image quality and reduced radiation exposure during UAE procedures.Additional details
Identifiers
Publishing Information
- Journal Title
- Cardiovascular and Interventional Radiology
- Journal Volume
- 41
- Journal Issue
- 3
- Journal Page Range
- p. 502-508
- ISSN
- 0174-1551
- CODEN
- CAIRDG
INIS
- Country of Publication
- United States
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 49107233
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- FLUOROSCOPY; GY RANGE; IMAGE PROCESSING; RADIATION DOSES; VASCULAR DISEASES; X RADIATION
- Descriptors DEC
- ABSORBED DOSE RANGE; BIOMEDICAL RADIOGRAPHY; CARDIOVASCULAR DISEASES; DIAGNOSTIC TECHNIQUES; DISEASES; DOSES; ELECTROMAGNETIC RADIATION; IONIZING RADIATIONS; MEDICINE; NUCLEAR MEDICINE; PROCESSING; RADIATION DOSE RANGES; RADIATIONS; RADIOLOGY
Optional Information
- Copyright
- Copyright (c) 2017 The Author(s)
- Notes
- http://www.springer-ny.com