Published June 1998
| Version v1
Journal article
X-ray fluorescence analysis of Fe - Ni - Mo systems
- 1. Nizhegorodskij Gosudarstvennyj Univ. im. N.I. Lobachevskogo, Nizhnij Novgorod (Russian Federation)
Description
Procedures for the X-ray fluorescence determination of the composition and thickness of Fe - Ni - Mo thin films and the concentration of elements in thick films of the Fe - Ni - Mo alloy are developed
Abstract (Russian)
Разработаны методики рентгеноспектрального флуоресцентного определения состава и толщины тонких пленок Fe - Ni - Mo и концентраций элементов в толстых пленках сплавов Fe - Ni - MoAdditional details
Additional titles
- Original title (Russian)
- Рентгеноспектральный флуоресцентный анализ систем Фе - Ни - Мо
Publishing Information
- Journal Title
- Zhurnal Analiticheskoj Khimii
- Journal Volume
- 53
- Journal Issue
- 6
- Journal Page Range
- p. 638-640
- ISSN
- 0044-4502
- CODEN
- ZAKHA8
INIS
- Country of Publication
- Russian Federation
- Country of Input or Organization
- Russian Federation
- INIS RN
- 31020557
- Subject category
- S37: INORGANIC, ORGANIC, PHYSICAL AND ANALYTICAL CHEMISTRY;
- Descriptors DEI
- IRON ALLOYS; MOLYBDENUM ALLOYS; NICKEL ALLOYS; QUALITATIVE CHEMICAL ANALYSIS; QUANTITATIVE CHEMICAL ANALYSIS; THIN FILMS; X-RAY FLUORESCENCE ANALYSIS
- Descriptors DEC
- ALLOYS; CHEMICAL ANALYSIS; FILMS; NONDESTRUCTIVE ANALYSIS; TRANSITION ELEMENT ALLOYS; X-RAY EMISSION ANALYSIS
Optional Information
- Notes
- 8 refs., 1fig., 3 tabs.