Inhaled Radon Progeny Dose Conversion Factors (DCF) for Real Population of a City
Creators
- 1. Zavod za zdravstvenu zastitu radnika, Nis (Serbia)
- 2. Univerzitet u Kragujevcu, Prirodno-matematicki fakultet, Kragujevac (Serbia)
Description
Dose conversion factor (DCF) of inhaled radon short lived progeny in human lung is defined as weighted effective dose in lung per unit exposure to radon progeny. It is given in units mSv/WLM. Calculation of DCF was conducted through the several successive steps by means of home written FORTRAN90 code. By using standard aerosol and subject related parameters, our code gave a value for DCF=16 mSv/WLM, that is close to 15 mSv/WLM that was recommended by ICRP66 (Marsh and Birchall). Then, we have varied subject related parameters based on statistical data about real population of Nis, city in the southeastern part of Serbia. Inhalation parameters and lung ventilation parameters have been varied according to sex, age and the kind of physical activity. Other parameters related to the atmosphere, weighting factors and the epithelia thickness have been kept on their best estimates. In this way a distribution of DCF for one real population has been acquired. It has been found that DCF is log normally distributed. (author)
Availability note (English)
Available from INIS in electronic form; Also available from Institute of Nuclear Sciences VINCAFiles
39086497.pdf
Files
(165.2 kB)
| Name | Size | Download all |
|---|---|---|
|
md5:6d0cc6b408ea5c585ea548888c548349
|
165.2 kB | Preview Download |
Additional details
Additional titles
- Original title (Serbian)
- Racunanje doznih konverzionih faktora (DFC) od udahmutih radonovih potomaka za realnu populaciju
Publishing Information
- Publisher
- Society for Electronics,Telecommunications, Computers, Automation, and Nuclear Technique, Belgrade, Serbia
- Imprint Place
- Belgrade (Serbia)
- Imprint Pagination
- 4 p.
- Report number
- INIS-RS--1412
Conference
- Title
- 52. Conference on Electronics, Telecommunications, Computers, Automation and Nuclear Technique (ETRAN)
- Original Conference Title
- 52.Konferencija za elektroniku, telekomunikacije, racunarstvo, automatiku i nuklearnu tehniku - ETRAN, Palic (Serbia) 8-12 juni 2008, Zbornik radova
- Dates
- 8-12 Jun 2008
- Place
- Palic (Serbia)
INIS
- Country of Publication
- Serbia
- Country of Input or Organization
- Serbia
- INIS RN
- 39086497
- Subject category
- S60: APPLIED LIFE SCIENCES;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- CALCULATION METHODS; DOSE EQUIVALENTS; DOSE LIMITS; INHALATION; LUNGS; PROGENY; RADIATION DOSES; RADON
- Descriptors DEC
- BODY; DOSES; ELEMENTS; FLUIDS; GASES; INTAKE; NONMETALS; ORGANS; RARE GASES; RESPIRATORY SYSTEM; SAFETY STANDARDS; STANDARDS
Optional Information
- Notes
- 7 refs., 1 figs., 2 tabs.