Published February 24, 1995 | Version v1
Report Open

Assessment of argon ion laser dispersive Raman spectroscopy for hot cell applications

Description

Characterization of high-level waste tank materials at Hanford is conducted to support safety assessments and waste treatment activities. Raman spectroscopy is expected to give chemical species information which may assist in defining layering in tank waste. This report describes the dispersive Raman system used in this year's investigation and the methology used to collect and evaluate data taken on tank waste samples. The current argon-ion Raman system was found not to be suitable for screening of tank cores, owing to silica interference, fluorescence interferences, and the extensive time required to collect and treat the data. Recommendations are given for further development

Availability note (English)

MF available from INIS under the Report Number; Also available from OSTI as DE95008431; NTIS; US Govt. Printing Office Dep.

Files

26055097.pdf

Files (1.5 MB)

Name Size Download all
md5:3f69a384355b42806875b1d31ab38724
1.5 MB Preview Download

Additional details

Publishing Information

Imprint Pagination
97 p.
Report number
WHC-SD--WM-RPT-098

Optional Information

Contract/Grant/Project number
Contract AC06-87RL10930
Funding organization
USDOE, Washington, DC (United States).