Published November 1966 | Version v1
Journal article

A practical method for evaluating the neutron dose equivalent rate

  • 1. Japan Atomic Energy Research Institute, Division of Health Physics and Safety, Tokai, Ibaraki (Japan)

Description

A practical method applicable to field monitoring with survey instruments is presented, which permits evaluation of the dose equivalent rate for neutrons, the spectrum of which is unknown but with energy ranging from epithermal to fast. The detectors employed consist of a BF3 proportional counter with paraffin moderators 6.5 cm and 1.0 cm thick, sheathed in 0.5 mm thick Cd, and a scintillation (ZnS and plastic) counter. The dose equivalent rate D)(mrem/hr) of neutrons with a broad spectrum is determined from the equation D=DB+DS, where DB is dose equivalent rate determined from the effective neutron flux and the effective neutron energy through the counting rates obtained with the BF3 proportional counter with paraffin moderators, and Ds the dose measured with the scintillation counter, the sensitivity of which is nearly proportional to the dose equivalent rate for neutrons above 2 MeV. The error in evaluating the dose equivalent rate by the present method has been calculated to be at most 60% for typical neutron spectra, in the energy range from epithermal to 10 MeV. (author)

Availability note (English)

Available from DOI: https://doi.org/10.1080/18811248.1966.9732368

Additional details

Publishing Information

Journal Title
Journal of Nuclear Science and Technology (Tokyo) (Online)
Journal Volume
3
Journal Issue
11
Journal Page Range
p. 473-478
ISSN
1881-1248

Optional Information

Notes
18 refs., 5 figs., 2 tabs., 1 photo