Published January 1985 | Version v1
Report Open

BTD building uranium mass balance study

Description

Fifteen test firings of depleted uranium (DU) munitions were made during the qualification study of the new target building at the BTD Range operated by the US Army Combat Systems Test Activity (CSTA) at Aberdeen Proving Ground, Maryland. Following these test firings, the total mass and mass distribution of DU inside the BTD facility was determined to define decontamination requirements for the new target building. 4 references, 17 figures, 17 tables

Availability note (English)

MF available from INIS under the Report Number; Available from NTIS, PC A04/MF A01 as DE85006276.

Files

16060316.pdf

Files (2.7 MB)

Name Size Download all
md5:e3a8fba45fab57f6d25c57676a26d15f
2.7 MB Preview Download

Additional details

Publishing Information

Imprint Pagination
60 p.
Report number
PNL--5344

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
16060316
Subject category
S54: ENVIRONMENTAL SCIENCES;
Resource subtype / Literary indicator
Numerical Data
Descriptors DEI
BUILDINGS; CHEMICAL ANALYSIS; DEPLETED URANIUM; DEPOSITION; EXPERIMENTAL DATA; MASS; SAMPLING; SPATIAL DISTRIBUTION; SURFACE CONTAMINATION
Descriptors DEC
ACTINIDES; CONTAMINATION; DATA; DISTRIBUTION; ELEMENTS; INFORMATION; METALS; NUMERICAL DATA; URANIUM