Published July 11, 2000 | Version v1
Journal article

Determination of through-going tracks' direction by means of δ-rays in the ICARUS liquid argon time projection chamber

Description

We exploited the crossing muon data, collected in the 50 l liquid argon TPC exposed at the CERN neutrino beam in 1997, to investigate the possibility of identifying the direction of minimum ionizing particle tracks relying only on δ-rays orientation. In this note we show that simple selection criteria allow using δ-rays down to very low energy (few MeV) with high efficiency and no misidentification of their direction. The Monte Carlo prediction - two recognized δ-rays per meter of track - is very well matched by the result of the scanning of the experimental data

Additional details

Identifiers

PII
S0168900299013844;

Publishing Information

Journal Title
Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
Journal Volume
449
Journal Issue
1-2
Journal Page Range
p. 42-47
ISSN
0168-9002
CODEN
NIMAER

Optional Information

Copyright
Copyright (c) 2000 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.