Published 1980 | Version v1
Report Restricted

Progress report on LLTR Series II Test A-2 (Part 1)

Description

This document contains a complete set of valid and final digital and analog data plots for LLTR Series II, Test A-2. Included is an Accuracy Statement regarding this data as required by Revision 0 of the GE Test Request, Specification No. 23A2062. The Series II, Sodium-Water Reaction Test A-2 was performed in the Large Leak Test Rig (LLTR) at the Energy Technology Engineering Center (ETEC). This was the third of three planned double-edged guillotine (DEG) rupture tests of a single tube which will be followed by a number of small leak tests. The test article is the LLTI which is a full-size diameter internals, shortened in length and prototypic of the CRBR steam generator. It is installed in the Large Leak Test Vessel (LLTV). The overall test program was formulated by General Electric (GE) as Test Requester to establish steam generator design and to verify analytical models/codes to estimate the effect of large leak accidents in an LMFBR demonstration plant steam generator and system

Availability note (English)

MF available from INIS under the Report Number; Available from NTIS., PC A15/MF A01 as DE82010136.

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

Additional details

Additional titles

Augmented title (English)
LMFBR

Publishing Information

Imprint Pagination
334 p.
Report number
DOE/SF/70030--T48