Published 1980 | Version v1
Report Open

Fast separation of isobars on ISOL facility collector

Description

Volatility of Rb, Sr, Y, Ba, some rare earth elements, Ra, Ac and Th, implantated in a tantalum collector with 45 keV energy is investigated. The collector heating during 180 s in vacuum results in the separation of implantated elements. Separation coefficients are as follows: sup(α)Sr/Rb=14/1390 K/, sup(α)Y/Sr=28/1680 K/, sup(α)La/Ba=8/1590 K/, sup(α)Sm/Eu=3/1470 K/, sup(α)Gd/Eu=22/1620 K/, sup(α)Tm/Yb=8/1600 K/, sup(α)Lu/Yb=38/1700 K/ and sup(α)Ac/Ra=sup(α)Th/Ra=030/1650 K/. The contributions of diffusion and desorption to the volatility process of implantated elements and prospects for application of the proposed method for separation of isobars on ISOL Facility collector are discussed

Availability note (English)

MF available from INIS under the Report Number.

Files

12580757.pdf

Files (243.4 kB)

Name Size Download all
md5:ce7e5455e624601fdfb00605118c640c
243.4 kB Preview Download

System files (30.8 kB)

Name Size Download all

Additional details

Additional titles

Original title (Russian)
Быстрое разделение изобар на коллекторе ISOL установок
Augmented title (English)
Radioisotopes of Rb, Sr, Sm, La, Tm, Y, Zr, Ba, Cd, Eu, Yb, Lu, Ra, Ac, Th

Publishing Information

Imprint Pagination
12 p.
Report number
JINR-R--6-13024

Optional Information

Notes
28 refs.; 8 figs.; 1 table; submitted to the journal Sov. Radiochem.