Published 1985 | Version v1
Book

Signal processing for underclad crack sizing

  • 1. Tetra Tech, Arlington, VA

Description

The techniques developed in this work provide a means of sizing underclad cracks and quality control methods for assessing the accuracy of the data. Data were collected with a minicomputer (LSI 11-02), a transient recorder (Biomaton 8100) and anti-aliasing filter. Three techniques were developed: the calibration curve, phase velocity and epicentral. The phase reversal characteristic in the data is a strong indication of the nature of the signal source. That is, cracks are clearly seperable from two isolated inclusions on the basis of observed phase reversal. These methods have been implemented on a computer and appear to provide an accurate rapid method to discriminate and size underclad cracks

Additional details

Publishing Information

Publisher
Plenum Press.
Imprint Place
New York, NY (USA)
Imprint Title
Quantitative nondestructive evaluation: 4A
Journal Page Range
p. 579-587.

Conference

Title
Progress in quantitative NDE.
Dates
8-13 Jul 1984.
Place
San Diego, CA (USA).