Published October 2002 | Version v1
Journal article

Performance design analysis of the supercritical pressure bottoming system of combined cycle power plants using once-through steam generator

  • 1. Seoul National Univ., Seoul (Korea, Republic of)
  • 2. Inha Univ., Incheon (Korea, Republic of)

Description

This study analyzed the design performance of the bottoming system of combined cycle power plants using a once-through heat recovery steam generator. For a parallel arrangement of the main heater and reheater, parametric analyses were carried out to present the criteria for determining the reheat pressure and the location of the starting point of the reheater in the HRSG. The performance of the bottoming system was presented for a range from high subcritical to supercritical pressure. The steam turbine power is as high as that of conventional triple-pressure bottoming systems. The serial arrangement of heat exchangers with division of each heater into several segments can achieve similar power level

Additional details

Publishing Information

Journal Title
Transactions of the Korean Society of Mechanical Engineers. B
Journal Volume
26
Journal Issue
10
Series
12 refs, 10 figs, 2 tabs
Journal Page Range
p. 1370-1377
ISSN
1226-4881

INIS

Country of Publication
Korea, Republic of
Country of Input or Organization
Korea, Republic of
INIS RN
36085945
Subject category
S42: ENGINEERING;
Descriptors DEI
BOTTOMING CYCLES; COMBINED CYCLES; DESIGN; HEAT EXCHANGERS; ONCE-THROUGH COOLING SYSTEMS; PERFORMANCE; POWER; STEAM TURBINES; SUPERCRITICAL STATE
Descriptors DEC
COOLING SYSTEMS; ENERGY SYSTEMS; EQUIPMENT; MACHINERY; THERMODYNAMIC CYCLES; TURBINES; TURBOMACHINERY