Mode completition and control in high-power gyrotron oscillators
Creators
- 1. Maryland Univ., College Park, MD (USA). Lab. for Plasma Research
Description
One of the problems in the design of high-power millimeter wave sources such as gyrotron oscillators is insuring that the device operates in the desired mode. For high-power and short-wavelength devices the effective mode density is high, in that the current is above threshold for many modes. One then is led to ask the following questions: Is operation in a single mode possible? What steps must be taken to maximize the electronic efficiency of the device while ensuring single-mode operation? The answer to the first question has been determined to be yes. Provided that certain conditions are met, single-mode operation is stable. However, for a given set of parameters there are many modes that are potentially the stable operating mode. This paper then attempts to address the second question regarding control of the operating mode
Additional details
Publishing Information
- Journal Title
- IEEE Transactions on Plasma Science
- Journal Volume
- 18
- Journal Issue
- 3
- Series
- IEEE Trans. Plasma Sci.
- Journal Page Range
- 260-272
- ISSN
- 0093-3813
- CODEN
- ITPSB
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 22000418
- Subject category
- S74: ATOMIC AND MOLECULAR PHYSICS;
- Descriptors DEI
- MICROWAVE AMPLIFIERS; MODE CONTROL; OSCILLATORS; PULSE GENERATORS; SPECIFICATIONS
- Descriptors DEC
- AMPLIFIERS; CONTROL; ELECTRONIC EQUIPMENT; EQUIPMENT; FUNCTION GENERATORS; MICROWAVE EQUIPMENT