Description
This study estimates organ and effective dose rate conversion coefficient for adult and child resulting from external gamma exposures due to radionuclide emissions using Monte Carlo technique. The calculations are carried out using computational phantoms representing the JCRP reference adult phantom and one-year old NCI-UF child phantom. The ratio of child to adult effective dose rate conversion coefficient is estimated and its dependency on the photon energy is observed. (author)
Additional details
Publishing Information
- Publisher
- Bhabha Atomic Research Centre
- Imprint Place
- Mumbai (India)
- Imprint Title
- Proceedings of the twentieth national symposium on environment - challenges in energy resource management and climate change
- Imprint Pagination
- 500 p.
- Journal Page Range
- p. 133-134
Conference
- Title
- 20. national symposium on environment - challenges in energy resource management and climate change
- Acronym
- NSE-20
- Dates
- 13-15 Dec 2018
- Place
- Gujarat (India)
INIS
- Country of Publication
- India
- Country of Input or Organization
- India
- INIS RN
- 53083797
- Subject category
- S61: RADIATION PROTECTION AND DOSIMETRY;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- DOSE RATES; GAMMA RADIATION; PERSONNEL DOSIMETRY; RADIATION DOSES; RADIATION MONITORING
- Descriptors DEC
- DOSES; DOSIMETRY; ELECTROMAGNETIC RADIATION; IONIZING RADIATIONS; MONITORING; RADIATIONS