Preliminary fabrication test of ceramic gas sensor for neutron irradiation tests

  • 1. Japan Atomic Energy Agency, Oarai Research and Development Center, Oarai, Ibaraki (Japan)

Description

It is important for neutron irradiation tests of materials and fuels to clarify the irradiation environment. Especially, the oxygen and hydrogen peroxide concentrations are required to measure for the analysis of corrosion mechanism of the structure materials in the Light-Water Reactor (LWR) conditions. On the other hand, it is necessary to develop the small and high-accuracy sensor because the outer diameter of the irradiation capsules used in JMTR is limited with φ65mm at a maximum. Thus, the small ceramic gas sensor combined stabilized-zirconia (YSZ) as oxygen ion conductor and platinum as electrode has been developed. In this report, the trial fabrication tests of the ceramic gas sensor carried out by the Spark Plasma Sintering (SPS) method and basic performance results of the sensor were described. (author)

Availability note (English)

Available from JAEA; DOI: https://doi.org/10.11484/jaea-testing-2009-010

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

System files (29.0 kB)

Name Size Download all

Additional details

Publishing Information

Imprint Pagination
22 p.
Report number
JAEA-Testing--2009-010

Optional Information

Notes
6 refs., 13 figs., 4 tabs.