Allogenic bone rods with freeze drying and gamma rays irradiation for treatment of fracture
Description
Opened reduction and internal fixation are the usual treatment of fracture, but both methods need a second operation for removal implants. The benefits of the bone rods are that they can avoid the removement of internal fixation and will be absorbed spontaneously. The bone rods are made of allogeneic compact bones with freeze-drying and gamma rays irradiation supplied by Shanxi Provincial Tissue Bank. The purpose of this study is to evaluate allograft reaction, the stability of the internal fixation, osteoinduction in the treatment of fracture using allogeneic bone rods with freeze drying and gamma rays irradiation. From May 1997 to May 1998, fourteen cases (male 12, female 2) of treatment were reviewed. The mean age was 37.3 (21-5 1). There were 3 medial malleolus fractures, 7 tibia and fibula fractures, 1 ulna and radius fracture, 1 lateral condyle of humerus fracture. The clinical results were satisfactory. Because the strength of the bone rods are weaker than that of screws, the bone rods are only indicated in the fixation of cancellous bones fracture and unloaded bone fracture. It can be used as a supplementary fixation of loaded bone. It is not indicated for fixation of comminuted fracture. More than two bone rods may be used in the fixation of fracture in order to get stability of the fracture and decrease stress between rods which will prevent the break of the bone rods. Allogeneic bone rods with freeze-drying and gamma rays irradiation can be used as implants of non-immunogenicity. There are no allograft reactions in all cases (including fever, leukocytosis, exudation or swelling in the wound). Although plenty of experimental studies have showed that freeze drying with gamma rays irradiation (below 50 KGy) would not destroy BMP of bone allograft, but there is no osteoinduction in our cases. The healing of a fracture and bridging external callus are similar as other operations. This new technique may have the following advantages compare with the screws: 1) there is no stress shielding, 2) no need for second operation for removing implants. Because there is no allograft reaction and lower price compared with other absorbable fixation material, we believe allogeneic bone rods with freeze drying and gamma rays irradiation are one of the excellent materials foic internal fixation
Additional details
Publishing Information
- Publisher
- Malaysian Institute for Nuclear Technology Research MINT, Bangi
- Imprint Place
- Bangi, Selangor (Malaysia)
- Imprint Title
- 7. International Conference on Tissue Banking: program and abstract book: poster session
- Imprint Pagination
- 127 p.
- Journal Page Range
- p. 120
Conference
- Title
- 7. International Conference on Tissue Banking
- Dates
- 24-26 Nov 1998
- Place
- Kuala Lumpur (Malaysia)
INIS
- Country of Publication
- Malaysia
- Country of Input or Organization
- Malaysia
- INIS RN
- 30033189
- Subject category
- S60: APPLIED LIFE SCIENCES;
- Resource subtype / Literary indicator
- Conference, Non-conventional Literature
- Descriptors DEI
- ANIMAL TISSUES; GAMMA RADIATION; GRAFTS; IRRADIATION; RADIOSTERILIZATION; SKELETON; TRANSPLANTS
- Descriptors DEC
- BODY; ELECTROMAGNETIC RADIATION; IONIZING RADIATIONS; IRRADIATION; ORGANS; RADIATIONS; STERILIZATION; TRANSPLANTS