LOFT emergency core coolant thermal analysis Class I review
Description
The LOFT Emergency Core Coolant Piping Thermal Analysis was checked to insure that the calculations made would conservatively satisfy the requirements in the LOFT technical specifications. Some of the boundary conditions used have not been shown to be conservative and require review and possible re-analysis. One of the thermal models used could not be clearly related to a specific part of the piping geometry and requires further explanation. The remainder of the models, the use of the SIMIR code and the other boundary conditions appear conservative and reflect normal thermal analysis methodology and practice. However, the use of constant, rather than temperature varying, thermal properties for some materials may introduce a slight error in these analyses
Availability note (English)
MF available from INIS under the Report Number; Available from NTIS., PC A02/MF A01.
Files
Additional details
Publishing Information
- Imprint Pagination
- 20 p.
- Report number
- LTR--113-48
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 9389364
- Subject category
- S61: RADIATION PROTECTION AND DOSIMETRY; S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Descriptors DEI
- ECCS; LOFT REACTOR; PIPES; SPECIFICATIONS; STRESS ANALYSIS
- Descriptors DEC
- PWR TYPE REACTORS; REACTOR PROTECTION SYSTEMS; REACTORS; RESEARCH AND TEST REACTORS; TANK TYPE REACTORS; TEST REACTORS; WATER COOLED REACTORS; WATER MODERATED REACTORS
Optional Information
- Secondary number(s)
- RE-A--77-123.