Published November 10, 2004 | Version v1
Journal article

Synchrotron Radiation Profile Monitor for the HERA Positron Beam

  • 1. Deutsches Elektronen-Synchrotron DESY, Notkestrasse 85, D-22603 Hamburg (Germany)

Description

For the measurement of the positron beam emittance at the e-p storage ring HERA at DESY a monitor is used which is based on the direct imaging of visible synchrotron radiation from a bending magnet. While the resolution of profile measurements by synchrotron radiation is already strictly limited by inherent effects, the observation in off-axis geometry modifies the measured vertical angular intensity distribution additionally. As a result the beam image is broadened due to the increased contribution of the diffraction limited resolution. In the present article detailed calculations concerning the image resolution especially in view of off-axis observation are presented. Furthermore the calculations indicate that the influence of resolution broadening effects may be overestimated by the standard formulas used as rule of thumb

Additional details

Identifiers

Publishing Information

Journal Title
AIP Conference Proceedings
Journal Volume
732
Journal Issue
1
Journal Page Range
p. 350-357
ISSN
0094-243X
CODEN
APCPCS

Conference

Title
11. beam instrumentation workshop
Dates
3-6 May 2004
Place
Knoxville, TN (United States)

Optional Information

Notes
(c) 2004 American Institute of Physics