The changers of time constant in the filters of DC logarithmic period meter - results and possibilities (1964)
- 1. Commissariat a l'Energie Atomique, Saclay (France). Centre d'Etudes Nucleaires
Description
The optimum transfer function for a DC logarithmic period-meter show that it is necessary to chose the time constant of the filters in accordance with the number of informations given by the neutron detector, if it is desirable to obtain short response time. Theoretical and experimental results of a DC logarithmic period-meter using a filter with time constants with level of the DC out put signal of the logarithmic amplifier are given when an DC ionization chamber is used. Theoretical results are also given when a neutron pulse detector is used. Prototype of the period-meter is also described. (author)
Availability note (English)
Available from INIS in electronic formAbstract (French)
L'expose debute par un rappel sur la determination de la fonction de transfert optimale pour un periodemetre logarithmique. Ce rappel permet de montrer qu'il est necessaire d'asservir les constantes de temps des filtres a la puissance neutronique. L'etude d'un periodemetre fonctionnant a partir de chambres d'ionisation et utilisant un systeme de filtrage a constantes de temps variable est ensuite developpee. Des resultats experimentaux obtenus a partir d'une maquette concretisent ce qui precede. On indique egalement une extension possible au traitement analogique des signaux fournis par d'autres types de detecteurs (chambres a fission - compteurs a BF 3). En conclusion du rapport, un prototype (le P.L.S.M.) est presente. (auteur)Files
36047779.pdf
Files
(650.7 kB)
| Name | Size | Download all |
|---|---|---|
|
md5:2a80b9c7d9ea5540823f80fc13437078
|
650.7 kB | Preview Download |
Additional details
Additional titles
- Original title (French)
- Variation des constantes de temps de filtrage dans les periodemetres logarithmiques. Resultats et possibilites (1964)
Publishing Information
- Imprint Pagination
- [36 p.]
- Report number
- CEA-R--2940
INIS
- Country of Publication
- France
- Country of Input or Organization
- France
- INIS RN
- 36047779
- Subject category
- S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
- Descriptors DEI
- ELECTRONIC EQUIPMENT; FREQUENCY ANALYSIS; IONIZATION CHAMBERS; NEUTRON DETECTORS; OPTIMIZATION; PERIODICITY; TRANSFER FUNCTIONS
- Descriptors DEC
- EQUIPMENT; FUNCTIONS; MEASURING INSTRUMENTS; RADIATION DETECTORS; VARIATIONS
Optional Information
- Notes
- 6 refs.