Published July 1979 | Version v1
Report Open

Computer simulation of natural circulation in FFTF secondary loops

Description

A thermal/hydraulic model of the FFTF secondary heat transport loop has been calibrated against transient natural circulation test data collected March to May 1979. The tests verified that the transition to natural convective flow could be effected from near isothermal conditions without excessive cooling at the air dump heat exchangers. Key empirical parameters of pressure drop and heat loss were found to be at 88% and 81% of pretest estimates, respectively. Pretest piping thermal transport and flow calculational models required no further revision to produce good agreement with test data

Availability note (English)

MF available from INIS under the Report Number; Available from NTIS., PC A02/MF A01.

Files

11541270.pdf

Files (5.2 MB)

Name Size Download all
md5:d63a4920fc52bd8080f20851570b5afc
5.2 MB Preview Download

Additional details

Publishing Information

Imprint Pagination
10 p.
Report number
HEDL-SA--1920S

Conference

Title
Specialists meeting on decay heat removal and natural circulation in FBR's.
Dates
28 - 29 Feb 1980.
Place
Upton, NY, USA.

Optional Information

Secondary number(s)
CONF-800226--2.