Published January 1997 | Version v1
Journal article

Estimation of accumulated dose of radiation by the method of ESR-spectrometry of dental enamel of mammals

  • 1. Russian Academy of Sciences, Moscow (Russian Federation). Inst. of Chemical Physics
  • 2. Russian Academy of Sciences, Moscow (Russian Federation). Inst. of Developmental Biology

Description

ESR-spectrometry was used to investigate radiation-induced paramagnetic centers in enamel of mammals: carnivores (polar bear and fox), ungulates (reindeer, European bison, moose), and man. Values at half the microwave power saturation of the radiation signal, P1/2, evaluated at room temperature, was found to range from 16 to 26 mW for animals and man. A new approach to discrimination of the radiation induced signal from the total ESR spectrum of reindeer enamel is proposed. ''Dose-response'' dependencies of enamel of different species mammals were measured within the dose range from 0.48 up to 10.08 Gy. Estimations of ''radiosensitivity'' enamel of carnivores and ungulates showed good agreement with radiosensitivity enamel of man by ESR method. (Author)

Additional details

Publishing Information

Journal Title
Applied Radiation and Isotopes
Journal Volume
47
Journal Issue
11-12
Journal Page Range
p. 1321-1328.
ISSN
0969-8043
CODEN
ARISEF

Conference

Title
4. international symposium on ESR dosimetry and applications.
Dates
15-19 May 1995.
Place