Published 1992 | Version v1
Book

The effect of isotope on the dosimetry of inhaled plutonium oxide

  • 1. Inhalation Toxicology Research Inst., Albuquerque, New Mexico (United States)
  • 2. Univ. of Florida, Gainsville, Florida (United States)

Description

Results of experimental studies in which animals inhaled 238PuO2 or 239PuO2 aerosols have shown that the biokinetics and associated radiation dose patterns for these two isotopes differ significantly due to differences in in-vivo solubility caused by the 260-fold difference in specific activity between 238PuO2 and 239PuO2. We have adapted a biokinetics and dosimetry model derived from results of the ITRI dog studies to humans and have calculated dose commitments and annual limits on intake (ALI) for both Pu isotopes. Our results show that the ALI calculated in this study is one-third that for class Y 238Pu from ICRP 30, and one-half or equal to that for class Y 239Pu, depending on how activity in the thoracic lymph nodes is treated dosimetrically. (author)

Part of:
8. International congress of the International Radiation Protection Association (IRPA8)

Additional details

Publishing Information

Publisher
International Radiation Protection Association
Imprint Place
Montreal, Quebec (Canada)
ISBN
1-55048-657-8
Imprint Title
8. International congress of the International Radiation Protection Association (IRPA8)
Imprint Pagination
2 v.
Journal Page Range
(v.1) p. 900-903

Conference

Title
8. international congress of the International Radiation Protection Association (IRPA8)
Dates
17-22 May 1992
Place
Montreal, Quebec (Canada)

Optional Information

Notes
10 refs., 2 tabs., 1 fig.