Time-resolved spectroscopy in the Rijnhuizen Tokamak Project tokamak

  • 1. Associatie Euratom-FOM, Nieuwegein (Netherlands). FOM-Instituut voor Plasmafysica
  • 2. Plasma Research Laboratory, Research School of Physical Science and Engineering, Australian National University, Canberra 0200 (Australia)
  • 3. Physics Faculty, University of Amsterdam, Amsterdam (Netherlands)

Description

At the Rijnhuizen Tokamak Project tokamak spectrometers are used to diagnose the velocity distribution and abundances of impurity ions. Quantities can be measured as a function of time, and the temporal resolution depends on the line emissivity and can be as good as 0.2 ms for the strongest lines. Several spectrometers, equipped with a charge-coupled device array, are being used with spectral ranges in the visible, the vacuum UV and the extreme UV. (orig.)