The excellent properties of CR 39 as a fast neutron detector are well known. The aim of this work was to develop a compound detector system which combines the advantages of CR 39 with the fast read-out of spark counting. Usually the detector films are read by optical equipment, which is very slow. A composite film consisting of a CR 39 film of 35 μm thickness and a polyester sheet of about 150 μm thickness has been manufactured which is resistant to the NaOH etchant. The effective evaluation technique of electrochemical etching was applied. (author)

Additional details

Publishing Information

Publisher
Pergamon.
Imprint Place
Oxford
ISBN
0-08-026509-X
Imprint Title
Solid state nuclear track detectors
Imprint Pagination
958 p.
Journal Page Range
p. 451-454.