The energy dependence of the neutron detection efficiency of the 0.953 cm thick NE-912 lithium glass scintillator has been measured by time-of-flight methods with a pulsed Van de Graff accelerator and a 0.935 cm thin Ne-908 lithium glass detector as standard. The measurements have been carried out for two different types of position of the thick galss detector. The energy ranges of measurements were 25 keV < Esub(n) < 2 MeV and 25 keV < Esub(n) < 1.2 MeV. The measured efficiency curve showed the marked effect of the 16O resonance at 442 keV, and a strong increase with energy for Esub(n) > 1.2 MeV, due to (n, n'γ) reactions

Additional details

Additional titles

Original title (no language)
Nejtronnaya fizika. Tom 4.

Publishing Information

Imprint Title
Neutron physics. Vol. 4
Journal Page Range
p. 310-322.
Report number
INIS-SU--315

Conference

Title
6. All-union conference on neutron physics.
Dates
2-6 Oct 1983.
Place
Kiev (Ukrainian SSR).

Optional Information

Notes