Evaluation of fatigue damage for wind turbine blades using acoustic emission
- 1. Korea Institute of Materials Science, Changwon (Korea, Republic of)
- 2. Dongshin University, Naju (Korea, Republic of)
- 3. Dept. of Physics, Pukyung National University, Busan (Korea, Republic of)
Description
In this study, the flap fatigue test of a 48 m long wind turbine blade was performed for 1 million cycles to evaluate the characteristics of acoustic emission signals generated from fatigue damage of the wind blades. As the number of hits and total energy continued to increase during the first 0.6 million cycles, blade damage was constant. The rise-time result showed that the major aspects of damage were initiation and propagation of matrix cracks. In addition, the signal analysis of each channel showed that the most seriously damaged sections were the joint between the skin and spar, 20 m from the connection, and the spot of actual damage was observable by visual inspection. It turned out that the event source location was related to the change in each channels total energy. It is expected that these findings will be useful for the optimal design of wind turbine blades
Additional details
Publishing Information
- Journal Title
- Journal of the Korean Society for Nondestructive Testing
- Journal Volume
- 35
- Journal Issue
- 3
- Series
- 5 refs, 15 figs
- Journal Page Range
- p. 179-184
- ISSN
- 1225-7842
INIS
- Country of Publication
- Korea, Republic of
- Country of Input or Organization
- Korea, Republic of
- INIS RN
- 46131167
- Subject category
- S42: ENGINEERING;
- Descriptors DEI
- ACOUSTIC EMISSION TESTING; CRACKS; DAMAGE; FATIGUE; INSPECTION; SIGNALS; TURBINE BLADES
- Descriptors DEC
- ACOUSTIC TESTING; MATERIALS TESTING; MECHANICAL PROPERTIES; NONDESTRUCTIVE TESTING; TESTING