Published November 1976 | Version v1
Journal article

Limits of detection of bismuth, antimony and cadmium by the method of inversion voltammetry at mercury electrodes

  • 1. Tomskij Politekhnicheskij Inst. (USSR)

Description

The limits of detection of Sb, Bi, and Cd have been estimated in inversion voltammetry with mercury film electrodes. The limits of detection are 1.5x10-12, 3x10-13, and 1.8x10-12 respectively. It has been shown that the increase in the electrolysis time to 60 min does not affect the compensation degree at constant coefficients for the first and second differences

Additional details

Additional titles

Original title (Russian)
Предел обнаружения висмута, сурьмы и кадмия методом амальгамной полярографии с накоплением с использованием полярографа вторых разностей

Publishing Information

Journal Title
Zh. Anal. Khim.
Journal Volume
31
Journal Issue
11
Series
Zh. Anal. Khim.
Journal Page Range
2150-2153

INIS

Country of Publication
USSR
Country of Input or Organization
USSR
INIS RN
9416628
Subject category
S37: INORGANIC, ORGANIC, PHYSICAL AND ANALYTICAL CHEMISTRY;
Descriptors DEI
CADMIUM COMPOUNDS; ELECTRODES; FILMS; MERCURY ALLOYS; POLAROGRAPHY; SENSITIVITY; TRACE AMOUNTS
Descriptors DEC
ALLOYS

Optional Information

Notes
For English translation see the journal J. Anal. Chem. USSR.