Published February 1987
| Version v1
Report
Open
Tuning of an rf cavity with a loop inside the cavity
Description
Tuning of an rf cavity with a moving loop inside the cavity is described. The formula to calculate the main parameters Δf and Q of the cavity are given. The results of tests are presented. The advantages of this method are analyzed
Availability note (English)
Available from NTIS, PC A02/MF A01; 1 as DE87008457.Files
19032787.pdf
Files
(170.8 kB)
| Name | Size | Download all |
|---|---|---|
|
md5:5e3430e2a7e62689d490532b493d50e7
|
170.8 kB | Preview Download |
Additional details
Publishing Information
- Imprint Pagination
- 8 p.
- Report number
- BNL--39543
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 19032787
- Subject category
- S43: PARTICLE ACCELERATORS;
- Descriptors DEI
- CAVITY RESONATORS; ELECTRIC COILS; NSLS; RF SYSTEMS; SPECIFICATIONS; TESTING; TUNING
- Descriptors DEC
- ELECTRICAL EQUIPMENT; ELECTRONIC EQUIPMENT; EQUIPMENT; RADIATION SOURCES; RESONATORS; SYNCHROTRON RADIATION SOURCES
Optional Information
- Notes
- Portions of this document are illegible in microfiche products.