Published July 2008 | Version v1
Miscellaneous

Microwave nondestructive detection of longitudinal crack in pipe with U-bend

  • 1. Tohoku Univ., Faculty of Engineering, Sendai, Miyagi (Japan)

Description

A circular electromagnetic TE11-mode is used for detection of longitudinal crack in a stainless steel pipe. To show the capability of microwave nondestructive testing for detection of crack in large and complex piping systems such as steam generator (SG) tube, inspected pipe including U-bend are examined in this study. (author)

Part of:
Proceedings of the 5th annual meeting of Japan Society of Maintenology

Additional details

Additional titles

Original title (Japanese)
Nippon hozen gakkai dai-5-kai gakujutsu koenkai yoshishu

Publishing Information

Imprint Title
Proceedings of the 5th annual meeting of Japan Society of Maintenology
Imprint Pagination
551 p.
Journal Page Range
p. 291-296

Conference

Title
5. annual meeting of Japan Society of Maintenology
Dates
10-12 Jul 2008
Place
Mito, Ibaraki (Japan)

Optional Information

Notes
6 refs., 9 figs., 1 tab. Imprint:Nippon hozen gakkai dai-5-kai gakujutsu koenkai yoshishu