Multisection dynamic CT perfusion for normal and tumorous pancreas
Creators
- 1. Cancer Hospital of Chinese Academy of Medical Sciences, Beijing (China). Dept. of Diagnostic Radiology
Description
Objective: To measure and assess CT perfusion for normal and cancerous pancreas by using multisection dynamic CT with tumor perfusion software package. Methods: The multisection dynamic CT perfusion series was performed for pancreatic perfusion with cine mode (1 s per rotation) on a multisection CT scanner (Lightspeed Ultra, GE, Waukesha, WI, USA), 4 x 5 mm collimation, 120 kV, 60 mA. Contrast injection was done by using 50 ml nonionic contrast agent (300 mgI/ml), at a flow rate of 3.5 ml/s with a power injector, and 5 seconds delay, and data acquisition lasted for 45 seconds. The mean BF, BV, MTT, and PS were measured and statistically analyzed in patients with normal pancreas (n=37), pancreatic carcinoma (n=37), and none-functioning islet cell tumor (n=3) proven by clinic and pathology, respectively, on a Sun Ultra AW4.0 workstation using Perfusion 2 software package (GE) with deconvolution method. Results: The mean BF, BV, MTT, and PS in normal pancreas tissue were (3386.2±1596.1) ml·min-1·kg-1, (267.3±130.2) ml·kg-1, (6.59±2.59) s, (288.2±203.9) ml·min-1·kg-1, respectively. The mean BF, BV, MTT, and PS in pancreatic carcinoma were (2323.1±1841.2) ml·min-1·kg-1, (189.7±160.6) ml·kg-1, (7.93±3.92) s, (457.2±261.6) ml·min-1·kg-1, respectively. The mean BF, BV, and PS between pancreatic carcinoma and normal pancreas were statistically significant (P= 0.01, 0.025, and 0.003). However, the mean MTT between pancreatic carcinoma and normal pancreas was not statistically significant (P=0.087). Conclusion: The pancreatic perfusion with multisection CT can be readily obtained. The mean BF, BV, and PS between pancreatic carcinoma and normal pancreas were statistically significant
Additional details
Publishing Information
- Journal Title
- Chinese Journal of Radiology
- Journal Volume
- 37
- Journal Issue
- 9
- Journal Page Range
- p. 845-849
- ISSN
- 1005-1201
INIS
- Country of Publication
- China
- Country of Input or Organization
- China
- INIS RN
- 36024725
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- BIOMEDICAL RADIOGRAPHY; BLOOD FLOW; CARCINOMAS; CAT SCANNING; CONTRAST MEDIA; DATA PROCESSING; DIAGNOSIS; DYNAMIC FUNCTION STUDIES; EVALUATION; IMAGES; PANCREAS; PATHOLOGY; PERFUSED ORGANS; SPIRAL CONFIGURATION; STATISTICS
- Descriptors DEC
- BODY; COMPUTERIZED TOMOGRAPHY; CONFIGURATION; DIAGNOSTIC TECHNIQUES; DIGESTIVE SYSTEM; DISEASES; ENDOCRINE GLANDS; GLANDS; MATHEMATICS; MEDICINE; NEOPLASMS; NUCLEAR MEDICINE; ORGANS; PROCESSING; RADIOLOGY; TOMOGRAPHY