Published August 15, 1991 | Version v1
Journal article

Measurement of the integral characteristics of radiation fields of medium-energy nulceons by plastic scintillation detectors

  • 1. AN SSSR, Moscow (USSR). Inst. for Nuclear Research

Description

We have developed a method for measuring the fluences of neutrons and protons with energies above 10-20 MeV and the corresponding dose equivalents by two plastic scintillation detectors of different sizes with an accuracy of 20%, and also method for determining the total dose equivalent of neutrons and protons by one detector with an accuracy of 40% in mixed fields of hadrons behind the proton accelerator shielding. (orig.)

Additional details

Publishing Information

Journal Title
Nuclear Instruments and Methods in Physics Research, Section A
Journal Volume
306
Journal Issue
1/2
Series
Nucl. Instrum. Methods Phys. Res., Sect. A.
Journal Page Range
343-349
ISSN
0168-9002
CODEN
NIMAE