Published November 2007 | Version v1
Journal article

Experimental validation of deviation of in-situ HPGe γ spectrometry

  • 1. Tsinghua Univ., Beijing (China). Dept. of Engineering Physics
  • 2. Northwest Inst. of Nuclear Technology, Xi'an (China)

Description

The measurement with in-situ HPGe γ spectrometry and the sampling analysis with laboratorial γ spectrometry have been carried out in a flat ground in one radioactive contaminated site. The deviation for the measuring results of in-situ HPGe γ spectrometry is validated by the comparison of in-situ HPGe γ spectrometry and sampling laboratorial analysis. The results show that relative to the results of laboratorial sample analysis, the deviations of in-situ γ spectrometry to 241Am, 137Cs, 60Co, 152Eu and 155Eu are -22%, 2%, 8%, -20% and 11% respectively. (authors)

Additional details

Publishing Information

Journal Title
Nuclear Electronics and Detection Technology
Journal Volume
27
Journal Issue
6
Journal Page Range
p. 1168-1170, 1185
ISSN
0258-0934

Optional Information

Notes
2 tabs., 8 refs.