Published 1984 | Version v1
Book

Automated cyclotron magnetic field measurement at the University of Manitoba

  • 1. Cyclotron Lab., Dept. of Physics, Univ. of Manitoba, Winnipeg, Manitoba R3T 2N2

Description

The magnetic field of the University of Manitoba compact cyclotron has been measured in high vacuum by polar scanning with 52 flip coils. This unique invacuo operation was required because the Curie effect on invar material is used to trim the field. The data acquisition controller was a Digital Equipment Corporation LSI-11 with CAMAC and IEEE-488 interfaces. Filtering, display and conventional equilibrium orbit analysis were performed off-line by means of a VAX-11/750 computer. A description of the apparatus and software is given

Additional details

Publishing Information

Publisher
Springer-Verlag New York, Inc.
Imprint Place
New York, NY (USA)
ISBN
0-387-13909-5
Imprint Title
Computing in accelerator design and operation
Journal Page Range
p. 411-415.

Conference

Title
Europhysics conference on computing in accelerator design and operation.
Dates
20-23 Sep 1983.
Place
Berlin (Germany, F.R.).