The GEPARD-2000 electromagnetic sectrometer is desinged and fabricated in IHEP in frames of the program of construction of the labelled neutrino complex. The detector consists of 2000 modules. Each module is 75x75 mm, its thickness is 20 rad. length by beam. The module consists of 40 scintillation and 40 lead plates (5 mm and 3 mm thick respectively). Using a thin plastic light guide covered by spectrum-shifting fiber light from each module is collected to FEhU 84-3. The GEPARD-2000 detector is characterized by high radiation resistance. Results of measuring energy resolution of the spectrometer mockup depending on the shower axis coordinate and accuracy of this coordinate determination and depending on the time coordinte value of electron incoming the detector are presented. 6 refs.; 3 figs