Published August 2014 | Version v1
Journal article

Monte Carlo simulations of Nai(Tl) spectra for measurements of semi-infinite plumes

  • 1. Health Canada, Radiation Protection Bureau, 775 Brookfield Rd., Ottawa, ON, K1A 1C1 (Canada)

Description

For the past 10 y Health Canada has operated a Fixed Point Surveillance Network of Nai(Tl) detectors across Canada. Deployed for both emergency response and daily monitoring of airborne radiation in the environment, a spectral stripping method allowed measurement of certain isotopes well below the ambient dose rate. These include 133Xe, 135Xe and 41Ar, typical of emissions from operating nuclear reactors. In an effort to increase the number of isotopes measured at these low levels a new technique of spectral fitting using spectral templates is being implemented. However, this requires very accurate spectral templates that can be difficult or impossible to obtain empirically for environmental measurements of airborne radio-isotopes. Therefore, a method of efficiently using Monte Carlo techniques to create these templates was developed. (authors)

Availability note (English)

Available from doi: http://dx.doi.org/10.1093/rpd/nct350

Additional details

Identifiers

Publishing Information

Journal Title
Radiation Protection Dosimetry
Journal Volume
160
Journal Issue
4
Journal Page Range
p. 277-282
ISSN
0144-8420

Conference

Title
Joint international Workshop on Off-site Gamma Dose Rate and Ground Contamination Measurements
Dates
13-16 May 2013
Place
Freiburg (Germany)

Optional Information

Notes
7 refs