Final Report of the 3rd Ex-Vessel Neutron Dosimetry Installation And Evaluations for Kori Unit 3 Reactor Pressure Vessel
Description
This report describes a neutron fluence assessment performed for the Kori Unit 3 pressure vessel belt line region based on the guidance specified in Regulatory Guide 1.190. In this assessment, maximum fast neutron exposures expressed in terms of fast neutron fluence (E>1 MeV) and iron atom displacements (dpa) were established for the belt line region of the pressure vessel. After Cycle 17 of reactor operation, 3rd Ex-Vessel Neutron Dosimetry Program was instituted at Kori Unit 3 to provide continuous monitoring of the belt line region of the reactor vessel. The use of the Ex-Vessel Neutron Dosimetry Program coupled with available surveillance capsule measurements provides a plant specific data base that enables the evaluation of the vessel exposure and the uncertainty associated with that exposure over the service life of the unit. Ex-Vessel Neutron Dosimetry has been evaluated at the conclusion of Cycle 18
Availability note (English)
Also available from KAERIFiles
42004546.pdf
Files
(40.8 MB)
| Name | Size | Download all |
|---|---|---|
|
md5:a06734e254cf817657172a925b88f358
|
40.8 MB | Preview Download |
Additional details
Publishing Information
- Imprint Pagination
- 258 p.
- Report number
- KAERI/CR--323/2009
INIS
- Country of Publication
- Korea, Republic of
- Country of Input or Organization
- Korea, Republic of
- INIS RN
- 42004546
- Subject category
- S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Descriptors DEI
- KORI-3 REACTOR; NEUTRON DOSIMETRY; NEUTRON FLUENCE; PRESSURE VESSELS; REACTOR OPERATION; REACTOR VESSELS; REGULATORY GUIDES
- Descriptors DEC
- CONTAINERS; DOCUMENT TYPES; DOSIMETRY; ENRICHED URANIUM REACTORS; OPERATION; POWER REACTORS; PWR TYPE REACTORS; REACTORS; THERMAL REACTORS; WATER COOLED REACTORS; WATER MODERATED REACTORS
Optional Information
- Notes
- 48 refs, 15 figs, 48 tabs