Published June 15, 1984 | Version v1
Report

Evaluating electrical cables by the LLNL Ease-Of-Ignition apparatus

Description

Using the LLNL Ease-of-Ignition apparatus, three physical characteristics of cables commonly used at LLNL were examined: (1) mass per unit length of cable, (2) the outside diameter, and (3) the percentage of conductor material. Trends in tests determining times-to-ignition that larger conductor diameters and ratios of conductor-to-outside diameter have ignition times dependent on the chemical composition of the jacket material were observed

Additional details

Publishing Information

Imprint Title
Hazards Control Department annual technology review, 1983
Journal Page Range
p. 35-42.
Report number