Published September 8, 2005 | Version v1
Journal article

Highly Sensitive Measurements of 222Rn Diffusion and Emanation

  • 1. Max Planck Institute for Nuclear Physics, Saupfercheckweg 1, 69117 Heidelberg (Germany)

Description

Highly sensitive techniques for determination of the 222Rn emanation from solids and diffusion through different membranes are presented. 222Rn and its daughters are measured via the alpha decays in special proportional counters at the absolute sensitivity of ∼30 μBq. Radon diffusion can be measured at the level of ∼10-13 cm2/s. Several samples were examined, e.g. stainless steel, teflon, various gaskets (emanation and diffusion measurements) and tanks. A combination of measurements of the 222Rn diffusion and emanation of thin nylon foils (used in the Borexino experiment) allowed the determination of 226Ra in the materials of interest at the level of ∼10-12 g/g 238U-equivalent

Additional details

Identifiers

Publishing Information

Journal Title
AIP Conference Proceedings
Journal Volume
785
Journal Issue
1
Journal Page Range
p. 142-149
ISSN
0094-243X
CODEN
APCPCS

Conference

Title
Topical workshop on low radioactivity techniques
Acronym
LRT 2004
Dates
12-14 Dec 2004
Place
Sudbury, ON (Canada)

Optional Information

Notes
(c) 2005 American Institute of Physics