Dose economy in radiodiagnosis. Present technical possibilities and development of normalisation

Creators

  • 1. Societe Massiot-Philips, 75 - Paris (France)

Description

Some aspects of the contribution of technological progress to dose saving are examined first. For radiography on film a new generation of intensifying screens is now available, with rare earths incorporated either as new luminophores or as activators of the layer. This can increase the speed of the screens by a factor of more than 5. In practice a compromise must be found at values under 5 to avoid the appearance of quantic noise on the radiograph, but dividing the dose by two, three or four without deterioration of the image is already a very appreciable result. Moreover the use of the luminance amplifier tube offers an approach to photographic radiology techniques, remarkable for their small dose consumption. Finally such devices as automatic exposers, memory storage of parameters, anatomical programming are likely to avoid certain human errors leading to failed shots

Abstract (French)

On examine d'abord quelques aspects de la contribution des progres technologiques dans le domaine de l'economie de doses. Pour la radiographie sur film, on dispose d'une nouvelle generation d'ecrans renforcateurs, dans la fabrication desquels on a introduit des terres rares, soit comme nouveaux luminophores, soit comme activateurs de la couche. On parvient ainsi a augmenter la rapidite des ecrans d'un facteur pouvant depasser 5. En pratique ont est amene a rechercher un compromis a des valeurs inferieures a 5 pour eviter l'apparition de bruit quantique sur la radiographie, mais la division de la dose par deux, trois ou quatre sans deterioration d'image constitue deja un resultat tres appreciable. Par ailleurs, l'utilisation du tube amplificateur de luminance permet l'acces a plusieurs techniques de prises de vues radiologiques, remarquables par les consommation reduite en dose: enfin, des dispositifs tels que: exposeurs automatiques, memorisation des parametres, programmation anatomique, sont susceptibles d'eviter un certain nombre d'erreurs humaines conduisant a des 'cliches rates'
Part of:
11. National congress on ionizing radiation monitoring

Additional details

Additional titles

Original title (French)
Economies de dose en radiodiagnostic

Publishing Information

Imprint Title
11. National congress on ionizing radiation monitoring, Nantes, 18-21 September 1979
Imprint Pagination
590 p.
Journal Page Range
p. 541-545.
Report number
FRNC-CONF--202

Conference

Title
11. National congress on ionizing radiation monitoring.
Dates
18 - 21 Sep 1979.
Place
Nantes, France.

INIS

Country of Publication
France
Country of Input or Organization
France
INIS RN
12599725
Subject category
S61: RADIATION PROTECTION AND DOSIMETRY;
Resource subtype / Literary indicator
Conference
Descriptors DEI
BIOMEDICAL RADIOGRAPHY; IMAGE CONVERTERS; IMAGE INTENSIFIERS; IMAGES; PHOTOGRAPHIC FILMS; RADIATION DOSES; RADIOLOGY
Descriptors DEC
DIAGNOSTIC TECHNIQUES; IMAGE TUBES; MEDICINE

Optional Information

Notes
Imprint:11. Congres national sur le controle des rayonnements ionisants, Nantes, 18-21 septembre 1979.