Dose economy in radiodiagnosis. Present technical possibilities and development of normalisation
Description
Some aspects of the contribution of technological progress to dose saving are examined first. For radiography on film a new generation of intensifying screens is now available, with rare earths incorporated either as new luminophores or as activators of the layer. This can increase the speed of the screens by a factor of more than 5. In practice a compromise must be found at values under 5 to avoid the appearance of quantic noise on the radiograph, but dividing the dose by two, three or four without deterioration of the image is already a very appreciable result. Moreover the use of the luminance amplifier tube offers an approach to photographic radiology techniques, remarkable for their small dose consumption. Finally such devices as automatic exposers, memory storage of parameters, anatomical programming are likely to avoid certain human errors leading to failed shots
Abstract (French)
On examine d'abord quelques aspects de la contribution des progres technologiques dans le domaine de l'economie de doses. Pour la radiographie sur film, on dispose d'une nouvelle generation d'ecrans renforcateurs, dans la fabrication desquels on a introduit des terres rares, soit comme nouveaux luminophores, soit comme activateurs de la couche. On parvient ainsi a augmenter la rapidite des ecrans d'un facteur pouvant depasser 5. En pratique ont est amene a rechercher un compromis a des valeurs inferieures a 5 pour eviter l'apparition de bruit quantique sur la radiographie, mais la division de la dose par deux, trois ou quatre sans deterioration d'image constitue deja un resultat tres appreciable. Par ailleurs, l'utilisation du tube amplificateur de luminance permet l'acces a plusieurs techniques de prises de vues radiologiques, remarquables par les consommation reduite en dose: enfin, des dispositifs tels que: exposeurs automatiques, memorisation des parametres, programmation anatomique, sont susceptibles d'eviter un certain nombre d'erreurs humaines conduisant a des 'cliches rates'Additional details
Additional titles
- Original title (French)
- Economies de dose en radiodiagnostic
Publishing Information
- Imprint Title
- 11. National congress on ionizing radiation monitoring, Nantes, 18-21 September 1979
- Imprint Pagination
- 590 p.
- Journal Page Range
- p. 541-545.
- Report number
- FRNC-CONF--202
Conference
- Title
- 11. National congress on ionizing radiation monitoring.
- Dates
- 18 - 21 Sep 1979.
- Place
- Nantes, France.
INIS
- Country of Publication
- France
- Country of Input or Organization
- France
- INIS RN
- 12599725
- Subject category
- S61: RADIATION PROTECTION AND DOSIMETRY;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- BIOMEDICAL RADIOGRAPHY; IMAGE CONVERTERS; IMAGE INTENSIFIERS; IMAGES; PHOTOGRAPHIC FILMS; RADIATION DOSES; RADIOLOGY
- Descriptors DEC
- DIAGNOSTIC TECHNIQUES; IMAGE TUBES; MEDICINE
Optional Information
- Notes
- Imprint:11. Congres national sur le controle des rayonnements ionisants, Nantes, 18-21 septembre 1979.