Published 1997 | Version v1
Report Open

PWR neutron ex-vessel detection calculations using three-dimensional codes

  • 1. Electricite de France (EDF), 69 -Villeurbanne (France)
  • 2. CEA Centre d'Etudes de Saclay, 91 -Gif-sur-Yvette (France). Direction des Reacteurs Nucleaires
  • 3. TRACTEBEL, Brussels (Belgium)

Description

During the accident of TM12, the signal delivered by source detectors was exceptionally high. This phenomenon was found out to be due to the water inventory in the primary system. Thus, in their research activity, Electricite de France (EdF) and Commissariat a l'Energie Atomique (CEA) have jointly launched a programme, whose aim was to determine to what extent the response of ex-vessel neutron detectors are representative of reactor water level (or sources positions) in a French 900 MWe PWR. In this framework, both partners developed the methods needed for each step of the calculation chain. Finally, a simulation of a LOCA indicates that the loss of coolant can be detected by existing monitoring system, and could be more efficiently found by changing the position of the source range detectors. (authors)

Availability note (English)

MF available from INIS under the Report Number.

Files

28064765.pdf

Files (264.1 kB)

Name Size Download all
md5:05b7727a8298340c99d650a98cc50ba7
264.1 kB Preview Download

Additional details

Additional titles

Original title (English)
Calculs de detection neutronique externe dans un rep

Publishing Information

Imprint Pagination
15 p.
Report number
EDF--97-NB-00012

Optional Information

Notes
11 refs.