Published 1998 | Version v1
Miscellaneous Open

The relative impact of sizing errors on steam generator tube failure probability

  • 1. Jozef Stefan Inst., Ljubljana (Slovenia)

Description

The Outside Diameter Stress Corrosion Cracking (ODSCC) at tube support plates is currently the major degradation mechanism affecting the steam generator tubes made of Inconel 600. This caused development and licensing of degradation specific maintenance approaches, which addressed two main failure modes of the degraded piping: tube rupture; and excessive leakage through degraded tubes. A methodology aiming at assessing the efficiency of a given set of possible maintenance approaches has already been proposed by the authors. It pointed out better performance of the degradation specific over generic approaches in (1) lower probability of single and multiple steam generator tube rupture (SGTR), (2) lower estimated accidental leak rates and (3) less tubes plugged. A sensitivity analysis was also performed pointing out the relative contributions of uncertain input parameters to the tube rupture probabilities. The dominant contribution was assigned to the uncertainties inherent to the regression models used to correlate the defect size and tube burst pressure. The uncertainties, which can be estimated from the in-service inspections, are further analysed in this paper. The defect growth was found to have significant and to some extent unrealistic impact on the probability of single tube rupture. Since the defect growth estimates were based on the past inspection records they strongly depend on the sizing errors. Therefore, an attempt was made to filter out the sizing errors and to arrive at more realistic estimates of the defect growth. The impact of different assumptions regarding sizing errors on the tube rupture probability was studied using a realistic numerical example. The data used is obtained from a series of inspection results from Krsko NPP with 2 Westinghouse D-4 steam generators. The results obtained are considered useful in safety assessment and maintenance of affected steam generators. (author)

Files

31018393.pdf

Files (588.0 kB)

Name Size Download all
md5:15867c8eb162a9f114c3012b495790e7
588.0 kB Preview Download
Part of:
Proceedings of the third international steam generator and heat exchanger conference

Additional details

Publishing Information

ISBN
0-919784-59-3
Imprint Title
Proceedings of the third international steam generator and heat exchanger conference
Imprint Pagination
839 p.
Journal Page Range
p. 176-188
Report number
INIS-CA--0073

Conference

Title
3. International steam generator and heat exchanger conference
Dates
Jun 1998
Place
Toronto, ON (Canada)

Optional Information

Notes
14 refs., 6 figs.