Early Faults and Characteristics of Large Capacity Non-salient Pole Synchronous Electric Machines

  • 1. State Grid Shandong Electric Power Research Institute, 250002 Jinan (China)
  • 2. School of Electric and Electronics Engineering, North China Electric Power University, 071003 Baoding (China)

Description

Large-capacity synchronous machines are prone to failure due to their complicated structure. The timely detection and processing in the early stage of the failure can avoid further expansion of the fault and avoid huge economic losses. By studying the structure of water-hydrogen-hydrogen turbine generators, this paper analyzes the types and characteristics of early faults of every component, and provides reference for the operation and state maintenance of synchronous machines. (paper)

Availability note (English)

Available from http://dx.doi.org/10.1088/1757-899X/576/1/012001

Additional details

Publishing Information

Journal Title
IOP Conference Series. Materials Science and Engineering (Online)
Journal Volume
576
Journal Issue
1
Journal Page Range
[9 p.]
ISSN
1757-899X

Conference

Title
International Conference on Advances in Materials, Mechanical and Manufacturing
Acronym
AMMM 2019
Dates
22-24 Mar 2019
Place
Beijing (China)

INIS

Country of Publication
United Kingdom
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
52113021
Subject category
S42: ENGINEERING;
Resource subtype / Literary indicator
Conference
Descriptors DEI
CAPACITY; HYDROGEN; MAINTENANCE; OPERATION; TURBINES
Descriptors DEC
ELEMENTS; EQUIPMENT; MACHINERY; NONMETALS; TURBOMACHINERY