Published July 1, 2019
| Version v1
Journal article
Early Faults and Characteristics of Large Capacity Non-salient Pole Synchronous Electric Machines
- 1. State Grid Shandong Electric Power Research Institute, 250002 Jinan (China)
- 2. School of Electric and Electronics Engineering, North China Electric Power University, 071003 Baoding (China)
Description
Large-capacity synchronous machines are prone to failure due to their complicated structure. The timely detection and processing in the early stage of the failure can avoid further expansion of the fault and avoid huge economic losses. By studying the structure of water-hydrogen-hydrogen turbine generators, this paper analyzes the types and characteristics of early faults of every component, and provides reference for the operation and state maintenance of synchronous machines. (paper)
Availability note (English)
Available from http://dx.doi.org/10.1088/1757-899X/576/1/012001Additional details
Identifiers
Publishing Information
- Journal Title
- IOP Conference Series. Materials Science and Engineering (Online)
- Journal Volume
- 576
- Journal Issue
- 1
- Journal Page Range
- [9 p.]
- ISSN
- 1757-899X
Conference
- Title
- International Conference on Advances in Materials, Mechanical and Manufacturing
- Acronym
- AMMM 2019
- Dates
- 22-24 Mar 2019
- Place
- Beijing (China)
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 52113021
- Subject category
- S42: ENGINEERING;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- CAPACITY; HYDROGEN; MAINTENANCE; OPERATION; TURBINES
- Descriptors DEC
- ELEMENTS; EQUIPMENT; MACHINERY; NONMETALS; TURBOMACHINERY