A numerical simulation method for predicting atmospheric flow and stack gas diffusion using a calculation domain of several km around a stack under complex terrain conditions containing buildings has been developed. The turbulence closure technique using a modified k-ε-type model without a hydrostatic approximation was used for flow calculation, and some of the calculation grids near the ground were treated as buildings using a terrain-following coordinate system. Stack gas diffusion was predicted using the Lagrangian particle model, that is, the stack gas was represented by trajectories of released particles. The developed numerical model was applied to a virtual terrain and building conditions in this study prior to the applications of a numerical model for real terrain and building conditions. The height of the additional building (Ha), located about 200 m leeward from the stack, was varied (i.e., Ha=0, 20, 30 and 50 m), and its effects on airflow and the concentration of stack gas at a released height of 75 m were calculated. Furthermore, effective stack height, which was used in the safety analysis of atmospheric diffusion for nuclear facilities in Japan, was evaluated from the calculated ground-level concentration of stack gas. The cavity region behind the additional building was calculated, and turbulence near the cavity was observed to decrease when the additional building was present. According to these flow variations with the additional building, tracer gas tended to diffuse to the ground surface rapidly with the additional building at the leeward position of the cavity, and the ground-level stack gas concentration along the plume axis also increased with the height of the additional building. However, the variations in effective stack height with the height of the additional building were relatively small and ranged within several m in this study. (author)

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

Part of:
Proceedings of 2009 international congress on advances in nuclear power plants

Additional details

Publishing Information

Imprint Title
Proceedings of 2009 international congress on advances in nuclear power plants
Imprint Pagination
[2572 p.]
Journal Page Range
[10 p.]
Report number
INIS-JP--123

Conference

Title
2009 international congress on advances in nuclear power plants
Acronym
ICAPP2009
Dates
10-14 May 2009
Place
Tokyo (Japan)

INIS

Country of Publication
Japan
Country of Input or Organization
Japan
INIS RN
43084220
Subject category
S22: GENERAL STUDIES OF NUCLEAR REACTORS;
Resource subtype / Literary indicator
Conference
Descriptors DEI
AIR FLOW; COMPUTERIZED SIMULATION; DIFFUSION; GASES; LAGRANGIAN FUNCTION; NUCLEAR FACILITIES; PLUMES; SAFETY ANALYSIS; STACKS; TURBULENCE; WIND TUNNELS
Descriptors DEC
EQUIPMENT; FLUID FLOW; FLUIDS; FUNCTIONS; GAS FLOW; SIMULATION

Optional Information

Notes
Available as CD-ROM Data in PDF format, Folder Name: FinalPaper, Paper ID: 9252.pdf; 12 refs., 12 figs.