New beam diagnostics at GANIL: very sensitive current transformers in beam lines and counting system of beam turns in cyclotrons
Description
Two new beam diagnostics have been designed and are in operation at GANIL: - To measure very small beam currents without intercepting the beam, transformers have been developed whose resolution is as low as 1 enA. That is obtained by ussing synchronous detectors locked on the PIG source pulsation and by reducing the noise level. - As the accelerated orbits in the second main cyclotron are overlapping one another, we cannot count the number of turns by a classical moving probe. Therefore we compute the cross-correlation function of the beam signals detected on inductive probes at the input and the output of the cyclotron. Due to the natural random beam structure, this cross-correlation function has a sharp maximum for the value of the beam time of flight. Thence the right number of beam turns can be calculated
Additional details
Publishing Information
- Journal Title
- IEEE Trans. Nucl. Sci.
- Journal Volume
- NS-32
- Journal Issue
- 5
- Series
- IEEE Trans. Nucl. Sci.
- Journal Page Range
- 1938-1940
- ISSN
- 0018-9499
- CODEN
- IETNA
Conference
- Title
- Particle accelerator conference.
- Dates
- 13-16 May 1985.
- Place
- Vancouver (Canada).
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 17051311
- Subject category
- S43: PARTICLE ACCELERATORS;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- BEAM CURRENTS; BEAM MONITORING; BEAM MONITORS; CYCLOTRONS; GANIL CYCLOTRON; PARTICLE BEAMS; TIME-OF-FLIGHT METHOD
- Descriptors DEC
- ACCELERATORS; BEAMS; CURRENTS; CYCLIC ACCELERATORS; HEAVY ION ACCELERATORS; ISOCHRONOUS CYCLOTRONS; MEASURING INSTRUMENTS; MONITORING; MONITORS
Optional Information
- Secondary number(s)
- CONF-850504--.