Published July 2012 | Version v1
Journal article

A study of a transportable thermal neutron radiography unit based on a compact RFI linac

  • 1. Kavala Institute of Technology, Kavala (Greece). Department of Electrical Engineering

Description

A transportable thermal neutron radiography system, incorporating a compact proton accelerator as neutron source has been simulated using the MCNP4B code. The neutron source will be produced via the 7Li(p,n)7Be reactions by a 2.5 MeV, 10 mA proton beam into a thick lithium target. Variable values for the collimator ratio were calculated. Thermal neutron radiography parameters are comparable to the research nuclear reactors. Sapphire filter was treated in order to improve the results. Simple and advanced neutron shielding materials considered which was further enhanced with layers of bismuth. The system was compatible with the European Union Directive on 'Restriction of Hazardous Substances' (RoHS) 2002/95/EC, hence excluding the use of cadmium and lead. (author)

Additional details

Publishing Information

Journal Title
Journal of Radioanalytical and Nuclear Chemistry
Journal Volume
293
Journal Issue
1
Journal Page Range
p. 95-101
ISSN
0236-5731
CODEN
JRNCDM

Optional Information

Notes
23 refs.