Published October 2004 | Version v1
Journal article

Two-dimensional electron cyclotron emission imaging diagnostic for TEXTOR

  • 1. FOM-Institute for Plasma Physics Rijnhuizen, Associatie EURATOM-FOM, Trilateral Euregio Cluster, 3430 BE, Nieuwegein (Netherlands)
  • 2. Plasma Physics Laboratory, P.O. Box 451, Princeton University, Princeton, New Jersey 08543 (United States)
  • 3. Department of Applied Science, 3001 Engineering Unit III, University of California, Davis, California 95616 (United States)

Description

A two-dimensional electron cyclotron emission imaging (ECEI) diagnostic has been developed in which broad bandwidth radiation is collected by a vertically aligned mixer array and separated by frequency band. Using a 16 element array, and an 8 band receiver attached to each array element, time-resolved 16x8 images of electron temperature profiles and fluctuations of the TEXTOR plasma are acquired with vertical and horizontal channel spacings of 11 and 8 mm, and spot sizes of 13 and 9 mm, respectively. The system is wideband tunable from 95 to 130 GHz, and the focus location may be shifted horizontally via translation of one of the optical imaging elements. System design and laboratory testing details of the ECE Imaging optics and multichannel wideband electronics are presented, together with TEXTOR plasma data

Additional details

Identifiers

Publishing Information

Journal Title
Review of Scientific Instruments
Journal Volume
75
Journal Issue
10
Journal Page Range
p. 3875-3877
ISSN
0034-6748
CODEN
RSINAK

Optional Information

Notes
(c) 2004 American Institute of Physics