Control rod efficiency during the xenon extrapoisoning
- 1. Gosudarstvennyj Komitet po Ispol'zovaniyu Atomnoj Ehnergii SSSR, Moscow (Russian Federation). Inst. Teoreticheskoj i Ehksperimental'noj Fiziki
Description
When power decreasing a reactor undergoes the xenon extrapoisoning. In the case takes place distortion of the neutron density and its gradient in dependence on the control rod position. Owing to the fact is changed the efficiency of a control rod, led into reactor, for example, for its shutdown. Efficiency change is analyzed for the most typical distortions of the neutron density and its gradient during the xenon extrapoisoning. The consideration is carried out in the one-group approximation for an one-dimensional case. 3 refs.; 2 figs
Additional details
Additional titles
- Original title (Russian)
- Эффективност' регулятора в йодной яме
Publishing Information
- Publisher
- Inst. Atomnoj Ehnergii.
- Imprint Place
- Moscow (Russian Federation)
- Imprint Title
- Problems of nuclear science and technology
- Imprint Pagination
- 104 p.
- Journal Issue
- no.1
- Series
- Fizika yadernykh reaktorov.;Fizika i metody rascheta yadernykh reaktorov.
- Journal Page Range
- p. 8-11.
- ISSN
- 0205-4671
- Report number
- INIS-RU--366
INIS
- Country of Publication
- Russian Federation
- Country of Input or Organization
- Russian Federation
- INIS RN
- 25018684
- Subject category
- S22: GENERAL STUDIES OF NUCLEAR REACTORS;
- Descriptors DEI
- ALGORITHMS; ANALYTICAL SOLUTION; CONTROL ROD WORTHS; CRITICALITY; DISTURBANCES; FLUX DENSITY; NEUTRON FLUX; POISONING; REACTOR SHUTDOWN
- Descriptors DEC
- RADIATION FLUX; SHUTDOWN