Verification of dosimetric commissioning accuracy of intensity modulated radiation therapy and volumetric modulated arc therapy delivery using task Group-119 guidelines
Creators
- 1. Department of Radiation Oncology, Krishna Institute of Medical Sciences, Secunderabad (India)
- 2. Centre for Biomaterials, Cellular and Molecular Theranostics, VIT University, Vellore (India)
- 3. Department of Physics, Osmania University, Hyderabad (India)
Description
The purpose of this study is to verify the accuracy of the commissioning of intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT) based on the recommendation of the American Association of Physicists in Medicine Task Group 119 (TG-119). Materials and Methods: TG-119 proposes a set of clinical test cases to verify the accuracy of IMRT planning and delivery system. For these test cases, we generated two sets of treatment plans, the first plan using 7-9 IMRT fields and a second plan utilizing two-arc VMAT technique for both 6 MV and 15 MV photon beams. The template plans of TG-119 were optimized and calculated by Varian Eclipse Treatment Planning System (version 13.5). Dose prescription and planning objectives were set according to the TG-119 goals. The point dose (mean dose to the contoured chamber volume) at the specified positions/locations was measured using compact (CC-13) ion chamber. The composite planar dose was measured with IMatriXX Evaluation 2D array with OmniPro IMRT Software (version 1.7b). The per-field relative gamma was measured using electronic portal imaging device in a way similar to the routine pretreatment patient-specific quality assurance. Results: Our planning results are compared with the TG-119 data. Point dose and fluence comparison data where within the acceptable confident limit. Conclusion: From the obtained data in this study, we conclude that the commissioning of IMRT and VMAT delivery were found within the limits of TG-119. (author)
Additional details
Publishing Information
- Journal Title
- Journal of Medical Physics
- Journal Volume
- 42
- Journal Issue
- 4
- Journal Page Range
- p. 258-265
- ISSN
- 0971-6203
INIS
- Country of Publication
- India
- Country of Input or Organization
- India
- INIS RN
- 51080984
- Subject category
- S61: RADIATION PROTECTION AND DOSIMETRY;
- Descriptors DEI
- ACCURACY; CLINICAL TRIALS; COMPUTERIZED TOMOGRAPHY; DOSE LIMITS; DOSIMETRY; PHOTON BEAMS; RECOMMENDATIONS
- Descriptors DEC
- BEAMS; DIAGNOSTIC TECHNIQUES; SAFETY STANDARDS; STANDARDS; TESTING; TOMOGRAPHY