Published December 2018 | Version v1
Journal article

A chemiluminescence aptasensor for thrombin detection based on aptamer-conjugated and hemin/G-quadruplex DNAzyme signal-amplified carbon fiber composite

  • 1. Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan, 250022 (China)

Description

Highlights: • SiO2@GO@CF was successfully prepared. • Aptamer was introduced and significantly improved the selectivity of chemiluminescence (CL) method. • G-quadruplex DNAzyme, as a signal-amplified material, improved the detection sensitivity. • The CL aptasensor was successfully used for thrombin determination in serum samples. In this work, a highly sensitive and selective chemiluminescence (CL) aptasensor was prepared for thrombin (THR) detection based on aptamer-conjugated and hemin/G-quadruplex DNAzyme signal-amplified carbon fiber composite (HG-DNAzyme/T-Apt/SiO2@GO@CF). Initially, SiO2@GO@CF was successfully prepared and characterized by Scanning Electron Microscopy (SEM), X-ray Diffraction (XRD) and Fourier Transform Infrared Spectroscopy (FT-IR). Thrombin aptamer (T-Apt) as an identification element and simulated enzyme - hemin/G-quadruplex DNAzyme (HG-DNAzyme) as a signal-amplified material, were applied in the CL aptasensor. Then, the immobilization properties of SiO2@GO@CF and adsorption properties of T-Apt/SiO2@GO@CF were studied. Lastly, HG-DNAzyme/T-Apt/SiO2@GO@CF was applied in construction of the CL aptasensor. When THR existed, HG-DNAzyme was desorbed from the surface of T-Apt/SiO2@GO@CF and catalyzed the CL system of luminol-H2O2. Under optimized CL conditions, THR was measured with the linear concentration range of 1.5 × 10−14 to 2.5 × 10−11 moL/L and the detection limit of 6.3 × 10−15 moL/L (3δ). The proposed CL aptasensor was used to the determination of THR in human serum samples and recoveries ranged from 99.0% to 102.4%. Those satisfactory results illustrated the CL aptasensor could achieve highly sensitive and selective detection of THR and revealed potential application in practical samples.

Availability note (English)

Available from http://dx.doi.org/10.1016/j.aca.2018.09.011

Additional details

Identifiers

DOI
10.1016/j.aca.2018.09.011;
PII
S0003267018310699;

Publishing Information

Journal Title
Analytica Chimica Acta
Journal Volume
1043
Journal Page Range
p. 132-141
ISSN
0003-2670
CODEN
ACACAM

Optional Information

Copyright
Copyright (c) 2018 Elsevier B.V. All rights reserved.