Published May 1984 | Version v1
Journal article

Experimental evaluation of improved dual temperature hydrogen isotopic exchange reaction system

  • 1. Hitachi Ltd., Ibaraki (Japan). Energy Research Lab.

Description

A proposed dual temperature hydrogen isotopic exchange reaction system between water and hydrogen gas is evaluated experimentally. The proposed system is composed of low temperature co-current reactors for reaction between water mists and hydrogen gas and high temperature co-current reactors for reaction between water vapor and hydrogen gas. Thus, operation is possible under atmospheric pressure with high reaction efficiency. Using the pilot test system which is composed of ten low temperature (30 0C) reaction units and ten high temperature (200 0C) reaction units, an experimental separation of deuterium from light water is carried out. The enrichment factor under steady state conditions, its dependency on operating time, and the reaction period necessary to obtain the steady state enrichment factor are determined experimentally and compared with calculations. It is shown that separation ability in a multistage reaction system can be estimated by numerical calculation using actual reaction efficiency in a unit reactor. (author)

Additional details

Publishing Information

Journal Title
J. Nucl. Sci. Technol. (Tokyo)
Journal Volume
21
Journal Issue
5
Series
J. Nucl. Sci. Technol. (Tokyo).
Journal Page Range
381-392
ISSN
0022-3131
CODEN
JNSTA