Published September 1977 | Version v1
Report Open

Experiment data report for semiscale Mod-1 test S-06-6 (LOFT counterpart test)

Description

Recorded test data are presented for Test S-06-6 of the Semiscale Mod-1 LOFT counterpart test series. These tests are among several Semiscale Mod-1 experiments conducted to investigate the thermal and hydraulic phenomena accompanying a hypothesized loss-of-coolant accident in a pressurized water reactor (PWR) system. Test S-06-6 was conducted from initial conditions of 15 792 kPa and 563 K to investigate the response of the Semiscale Mod-1 system to a depressurization and reflood transient following a simulated double-ended offset shear of the broken loop cold leg piping. During the test, cooling water was injected into the cold leg of the intact loop to simulate emergency core coolant injection in a PWR. The heater rods in the electrically heated core were operated at an axial peak power density which was 75% of the maximum peak power density (52.5 kW/m). Test S-06-6 also evaluated the effect of special hardware assumptions on the core response

Availability note (English)

MF available from INIS under the Report Number; Available from NTIS., PC A13/MF A01.

Files

9362917.pdf

Files (12.0 MB)

Name Size Download all
md5:ef44948036e1cc7a702a84bda0c26c89
12.0 MB Preview Download

Additional details

Additional titles

Augmented title (English)
PWR

Publishing Information

Imprint Pagination
285 p.
Report number
TREE-NUREG--1126